GE Transformer Power Distribution Solutions

Tailored switchgear and power distribution packages designed for the unique requirements of each industry — from specification through commissioning.

Manufacturing power distribution
Manufacturing

Industrial Manufacturing Solutions

Production lines demand uninterrupted power with precise motor control. Our manufacturing solutions combine low voltage switchgear with integrated motor control centers, coordinated protection schemes, and Modbus RTU communication for SCADA integration.

  • LV switchgear assemblies rated up to 4000A
  • Withdrawable MCC with individual motor protection
  • Selectivity coordination studies included
  • IEC 61439 type-tested, arc-flash rated
Data center power distribution
Data Centers

Data Center Power Infrastructure

Tier III and IV data centers require redundant power distribution with zero-transfer-time switchover. Our data center solutions feature dual-fed switchboards, static transfer switches, and intelligent power monitoring with IEC 61850 communication.

  • 2N redundant distribution architecture
  • Busbar trunking for flexible rack power feeds
  • Per-circuit power monitoring with Modbus TCP
  • Hot-swappable component design for zero downtime
Commercial building switchgear
Commercial Buildings

Commercial & Institutional Buildings

Offices, hospitals, and educational campuses require compact switchgear that fits tight mechanical rooms while meeting strict fire and safety codes. Our commercial solutions prioritize space efficiency, energy metering, and code compliance.

  • Compact main distribution switchboards
  • Integrated energy metering for tenant billing
  • Emergency and standby power distribution
  • NFPA 70 and IEC 60364 compliant designs
Energy sector switchgear
Energy & Utilities

Energy Generation & Distribution

Power plants and substations operate under extreme fault current conditions. Our utility-grade switchgear features 100kA breaking capacity, IP65 outdoor enclosures, and protection relay integration for fully automated fault isolation.

  • Medium voltage switchgear up to 36kV
  • 100kA short-circuit withstand capability
  • IP65 outdoor rated enclosures
  • IEC 61850 GOOSE messaging support

Our Project Delivery Process

From your single-line diagram to a commissioned installation

01

Specification Review

Our application engineers review your SLD and project requirements within 48 hours.

02

Design & Verification

Detailed design per IEC 61439 with full verification reports and approval drawings.

03

Manufacturing & Testing

Factory assembly with routine testing per IEC 61439-1 and individual test certificates.

04

Delivery & Commissioning

Logistics coordination, on-site installation support, and commissioning assistance.

Ready to Discuss Your Project?

Share your project specifications and our engineering team will prepare a tailored proposal.